Address
Shuangyu Road Leshang Pioneer Prak
Yueqing Bay Area Yueqing City Zhejiang Province 325600 China

Work Hours
Monday to Friday: AM - 7PM
Weekend: 10AM - 5PM

HLC-3XQ04CG(3P/40A/24VAC) Definite Purpose Contactor

Original price was: $22.00.Current price is: $20.00.

HLC-3XQ04CG(3P/40A/24VAC) Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 277V Or 600V The Nominal Current Up To The 40A Electric Circuit, Is Suitable For The Starting And The Control Three-Phase Motor (Or Compressor) And Other Three-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

501 in stock (can be backordered)

*Applicable and Description

1. Applicable Scope

HLC-3XQ04CG(3P/40A/24VAC) Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 277V Or 600V The Nominal Current Up To The 40A Electric Circuit, Is Suitable For The Starting And The Control Three-Phase Motor (Or Compressor) And Other Three-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

2.Type and Meaning

HLC3XQ04CG 
Hongli ElectricContactorsPackagingPole FormCoil VoltageContact RatingTermination 
“Y” :Individual Box Pack3X : 3PoleQ:24AC04:40FLACG: #14-4 Lug with dual QC 
 
*Product Explanation And Main Technical Parameter
TypeHLC-3XQ04CG(3P/40A/24VAC) Definite Purpose Contactor
StandardIEC60947UL508
Rating of CurrentIe 40AFLA: 40A
Rating of Contacts VoltageUe 240/277V240/277/480/600VAC
Rating of Insulation VoltageUi 660V600V
Rating of Coil VoltageUs 24VUs 24V
Mechanical Life1000,000 Cycle1000,000 Cycle
Electricity life100,000 Cycle250,000 Cycle
Product Explanation

1.Product Description

HLC-3XQ04CG Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 600v, Fixed Operating Current To 40A Three-Phase Load Circuit Control,At Present, Widely Applies To The Three-Phase Mechanical Device Main Circuit As Well As The Three-Phase Air-Conditioner Compressor Control.

2 .The Regular Service Conditon And Installs The Condition
a. In The Surrounding Air Temperature The Limiting Value Is +65°C , Gets
Down The Limiting Value Is -25°C
b. The Installation Site Elevation Does Not Surpass 2000m
c. The Air Pollution Rank Is 2 Levels
d. Installs The Category Is II ;
e. Installment Facing The Gradient Does Not Surpass ±5°C
f. Not Remarkable Undulation, Impact And Vibration Place.

3 .Main Technical Parameter
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably
Working, Its Drop Out Voltage In 20% ~ 70%Us
b. Contactor Use Category: Ac-1 Ac-8a
c. Contactor In With 0.4m Place, Its Noise Below 40db.

4 . Installing Specification And Install Size

a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°C

b. Before The Use Should Inspect The Power Terminal And The Contactor
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating
The Breakdown, Behind Check Off May Electrify Tries .

 
*Conforms To The Standard
Conforms To National Standard And International Standard1 Conforms To UL508, IEC60947, GB14048Standard
2 Approved By UL,CUL,TUV,CE,CCC,Safe Certification and ISO9001 System Certification(SGS)

CCC Certificate Number:  2005010309156761

UL Files Number: E251539

*Ordering Request

In Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order.

Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc
If You Request As Follows: Nominal Current: 40A, Working Voltage: 240/277V,480V,600V, Pole Number: Three Pole Without Shunt, Coil Control Voltage:24V, Wiring Way: Quick Connect, Load Current: Three-Phase Motor Controls Or Heating Load, Packing: 25/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : HLC-3XQ04CG

Lifts The Samples As Follows (Contains Derivation Type From This Model)

Rating of Current

Ie

PoleRating of Coil Control VoltageControl Motor Power
24VAC120VAC208/240VAC277VAC380/480VAC240VAC
40A3PHLC-3XQ04CGHLC-3XT04CGHLC-3XU04CGHLC-3XV04CGHLC-3XH04CG7.5Kw
*Applicable and Description
1. Applicable Scope HLC-3XQ04CG(3P/40A/24VAC) Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 277V Or 600V The Nominal Current Up To The 40A Electric Circuit, Is Suitable For The Starting And The Control Three-Phase Motor (Or Compressor) And Other Three-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.
2.Type and Meaning
HL C 3X Q 04 CG
Hongli Electric Contactors

Packaging

Pole Form

Coil Voltage

Contact Rating

Termination

“Y” :Individual Box Pack 3X : 3Pole Q:24AC 04:40FLA CG: #14-4 Lug with dual QC
*Product Explanation And Main Technical Parameter
Type HLC-3XQ04CG(3P/40A/24VAC) Definite Purpose Contactor
Standard IEC60947 UL508
Rating of Current Ie 40A FLA: 40A
Rating of Contacts Voltage Ue 240/277V 240/277/480/600VAC
Rating of Insulation Voltage Ui 660V 600V
Rating of Coil Voltage Us 24V
Mechanical Life 1000,000 Cycle 1000,000 Cycle
Electricity life 100,000 Cycle 250,000 Cycle
Product Explanation 1.Product Description HLC-3XQ04CG Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 600v, Fixed Operating Current To 40A Three-Phase Load Circuit Control,At Present, Widely Applies To The Three-Phase Mechanical Device Main Circuit As Well As The Three-Phase Air-Conditioner Compressor Control. 2 .The Regular Service Conditon And Installs The Condition a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets Down The Limiting Value Is -25 b. The Installation Site Elevation Does Not Surpass 2000m c. The Air Pollution Rank Is 2 Levels d. Installs The Category Is Ii ; e. Installment Facing The Gradient Does Not Surpass ±5° f. Not Remarkable Undulation, Impact And Vibration Place. 3 .Main Technical Parameter a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably Working, Its Drop Out Voltage In 20% ~ 70%Us b. Contactor Use Category: Ac-1Ac8a c. Contactor In With 0.4m Place, Its Noise Below 40db. 4 . Installing Specification And Install Size a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5° b. Before The Use Should Inspect The Power Terminal And The Contactor Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating The Breakdown, Behind Check Off May Electrify Tries .
*Conforms To The Standard
Conforms To National Standard And International Standard 1 Conforms To UL508, IEC60947, GB14048Standard
2 Approved By UL,CUL,TUV,CE,CCC,Safe Certification and ISO9001 System Certification(SGS)
CCC Certificate Number:  2005010309156761 UL Files Number: E251539
*Ordering Request
In Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order. Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc
If You Request As Follows: Nominal Current: 40A, Working Voltage: 240/277V,480V,600V, Pole Number: Three Pole Without Shunt, Coil Control Voltage:24V, Wiring Way: Quick Connect, Load Current: Three-Phase Motor Controls Or Heating Load, Packing: 25/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : HLC-3XQ04CG
Lifts The Samples As Follows (Contains Derivation Type From This Model)
Rating of Current Ie Pole Rating of Coil Control Voltage Control Motor Power
24VAC 120VAC 208/240VAC 277VAC 380/480VAC 240VAC
40A 3P HLC-3XQ04CG HLC-3XT04CG HLC-3XU04CG HLC-3XV04CG HLC-3XH04CG 7.5Kw
Weight 0.48 kg
Dimensions 10 × 6.5 × 8 cm
upc

6970307190367

Reviews

There are no reviews yet.

Be the first to review “HLC-3XQ04CG(3P/40A/24VAC) Definite Purpose Contactor”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

You may also like…

en_USEnglish
Powered by TranslatePress
Verified by MonsterInsights